Find Similar Products

Basic Info.

Model NO.
H003
Protection Grade
IP68
Cable Ports
2-4 Ports
Application
Aerial, Duct, Burial
OEM ODM
Acceptable
Itrem Certification
RoHS
Cable Diameter
Max 14mm
Max.Capacity
96
Warranty
12 Months
Item
Horizontal Fiber Closure, Distribution Box
Box Material
Modified Polymer Plastic
Transport Package
Standard Carton
Specification
280× 200× 90MM
Trademark
SOFTEL or manual
Origin
Zhejiang, China
HS Code
85367000
Production Capacity
50000PCS/ Year

Product Description

China Supplier 12-24 Fiber Optic Joint Splice Closure

Description

1. Mechanical seal: Excellent seal performance, reusable. Protection grade is IP68.
2. Installation method: Wall-mounted, pole-mounting, manhole
3. L× W× H: 280× 200× 90MM
4. Cable ports: 2-4 ports
5. Cable Diameter: Max φ 14
6. Max. Capacity (bunchy fiber): 96
7. Core capacity per tray: 12 or 24
China Supplier 12-24 Fiber Optic Joint Splice Closure
China Supplier 12-24 Fiber Optic Joint Splice Closure

China Supplier 12-24 Fiber Optic Joint Splice Closure

Characteristic

1. Easy to re-enter Cable entry/exit ports
2. Pressure testing valve and earth deriving device
3. Intergrated seal, air tight and water proof Ideal for cable repair
4. RoHS compliant Can be used in through, branch or mid span splice locations
5. Suitable for aerial, underground duct or direct burial applications
 
 Item Parameters  
1                                   L×W×H   280×200×90MM
2 Cable ports 2-4 ports
3  Cable Diameter Max φ14
4 Max.Capacity (bunchy fiber)      96
5   Core capacity per tray   12 or 24 Holds up to 96 fibers
Box material Modified polymer plastic 
1. Scope of application
This Installation Manual suits for the Fiber Optic Splice Closure (Hereafter abbreviated as FOSC), as the guidance of proper installation.
 
The scope of application is: aerial and wall-mounting. The ambient temperature ranges from -40 to 65ºC.
 
2. Basic structure and configuration 
2.1 Dimension and capacity
Outside dimension (LxWxH) 280x200x90 (mm)
Weight (excluding outside box) 1200g-1500g
Number of inlet/outlet ports max. 4 pieces
Diameter of fiber cable Φ8-Φ14 (mm)
Capacity of FOSC Bunchy: 6-96 (Cores)
 
2.2 Main components
No. Name of components Quantity Usage Remarks
1 FOSC cover 1 piece Protecting fiber cable splices in whole Internal diameter:
205x146 (mm)
2 FOSC bottom 1 piece Fixing reinforced core, fiber cable and FOST Internal diameter:
205x146 (mm)
3 Fiber optic splice tray
(FOST)
max. 4 pieces (bunchy) Fixing heat shrinkable protective sleeve and holding fibers Suitable for:
Bunchy:6,12,24(cores) 
4 Integrated seal fitting 1 set Sealing between FOSC cover and FOSC bottom  
5 Port plug 2 pieces Sealing empty ports  
6 Earthing deriving device 1 set Deriving metallic components of fiber cable in FOSC for earthing connection. Configuation as per requirement.
 
 
2.3 Main accessories and special tools
No. Name of accessories Quantity Usage Remarks
1 Heat shrinkable protective sleeve   Protecting fiber splices Configuration as per capacity
2 Nylon tie   Fixing fiber with protective coat Configuration as per capacity
3 Seal tape 1 roll Enlarging diameter of fiber  cable which fits in with seal fitting Configuration as per specification
4 Hanging hook 1 set For aerial use Configuration as per requirement
5 Fixing device 1 set   Configuration as per requirement
6 Earthing wire 1 piece Putting through between earthing devices To put through while required
7 Abrasive cloth 1 piece Scratching fiber cable  
8 Labeling paper 1 piece Labeling fiber  
9 Special wrench 1 piece Fixing octagonal nut (plastic)  
10 Buffer tube
 
To be decided by customers Hitched to fibers and fixed with FOST, managing buffer Configuration as per requirement
11 Desiccant 1 bag Put into FOSC before sealing for desiccanting air.  
 
 
3.  Necessary tools for installation
3.1 Supplementary materials (to be provided by operator)
Name of materials Usage
Scotch tape Labeling, temporarily fixing
Ethyl alcohol Cleaning
Gauze Cleaning
 
3.2 Special tools (to be provided by operator)
Name of tools Usage
Fiber cutter Cutting off fibers
Fiber stripper Strip off protective coat of fiber cable 
Combo tools Assembling FOSC
 
3.3 Universal tools (to be provided by operator)
Name of tools Usage and specification
Band tape Measuring fiber cable
Pipe cutter Cutting fiber cable
Electrical cutter Take off protective coat of fiber cable
Combination pliers Cutting off reinforced core
Screwdriver Crossing/Paralleling screwdriver
Scissor  
Waterproof cover Waterproof, dustproof
Metal wrench Tightening nut of reinforced core
 
3.4  Splicing and testing instruments (to be provided by operator)
Name of instruments Usage and specification
Fusion Splicing Machine Fiber splicing
OT DR Splicing testing
Provisional splicing tools Provisional testing
 
Notice: The above-mentioned tools and testing instruments should be provided by the operators themselves.
 

4.  Installation flow chart
 

The process of installing FOSC
Step One - Open the closure
 Cleaning the locale and determine where to install the FOSC and then place 

Check whether the main components and accessories have been well prepared 
inside the package.
Open the closure by demounting the fixing bolt (5 pieces) of the housing, then succeed in
opening the closure. 
 See Drawing 1
Important issues: If the weather condition is not good enough, then a tent must be pitched
for waterproof and dustproof.

 
5.2  Step Two -Determine length of fiber cable to be fixed and stripped inside FOSC
5.2.1   . Fiber cable in 70mm length: the distance from seal fitting to fiber cable pressboard
. Fiber cable in 1720mm length: it is used to be winded and spliced after stripping.
    . Fiber with protective coat in 120mm length: the distance from the fixing point of fiber cable to the fixing point of FOST (fiber optic splice tray).
 . Fiber in 1600mm length: after stripping off the protective coat, it is to be winded inside the FOST after splicing with other fibers
5.2.2   See Drawing 2
Important issues:
Reserve enough length of fiber cable to be spliced.
Stripping length also could be decided by customer according to installation requirement.
 

5.3  Step Three - Strip off fiber protective coat of fiber cable and fiber
5.3.1  Strip off protective coat of fiber cable from the temp. locating mark with the cutter and the
stripper, please refer to Drawing 2 for stripping length. Stripping length also could be
decided according to installation requirement 
5.3.2  See Drawing 3. 
Important issues:  If it is difficult to strip off all the protective coat of fiber cable at one time,
  strip it off section by section to avoid fiber breakage.

5.4  Step Four - Separate fiber cores and prepare work prior to fixing fiber.
 Wind 2 layers of insulation tape on protective coat of fiber core. Meanwhile, get rid of
 the stuffing to separate fiber and clean them. Form a ring with the diameter of 100mm
 or so and fix it on the fiber temporarily by adhesive tape.
   This FOSC is provided with 2 inlet/outlet tubes, each of which suit for 1 piece of fiber
 cable with max. diameter ф14mm or 2 pieces of fiber cable with max. diameter
ф11mm. The corresponding port plug could be taken out according to number of fiber
 cable actually required. The max. number of fiber cables with diameter ф11mm to be installed is 4.
   5.4.3  Reserve reinforced core in 30mm length and cut off the unnecessary ones.
5.4.4  See Drawing 4
Important Issues: Cut off reinforced core with a special cutting plier.  

 
5.5  Step Five - Fix reinforced core and fiber cable
5.5.1  After deciding number of fiber cable inlet/outlet, demount the nut and gasket of the
corresponding inlet/outlet tube. Insert them into fiber cables in sequence, which are to be
inserted into inlet/outlet tube then.
 Fix fiber cable to fixing device of fiber cable (while diameter of fiber cable is small,
   enlarge the diameter with insulation tape), then fix the reinforced core to the fixing device
of the reinforced core.
Push the first gasket into inlet/outlet tube, then enlarge the diameter of fiber cable with
seal tape (to fit in with internal diameter of inlet/outlet tube). Then push the second
gasket and the seal tape into inlet/outlet tube, which is to be tightened with octagonal
nut.
See Drawing 5
Important issues: before the seal tape is used for enlarging the diameter of fiber cable, it should be scratched and to be cleaned with abrasive cloth and ethyl alcohol.

5.6  Step Six - Splice fibers
5.6.1 Follow user manual of fusion splicing machine to splice fiber.
Important issue: pay attention to the twist and bend of fiber.
 
 Step Seven -Install heat shrinkable protective sleeve and house fibers
5.7.1  When having completed splicing the fibers, the first fiber ring should be housed
on the farthest side of FOST, the remaining fiber should be winded, forming a ring
with diameter not less than 80mm. then put it into FOST (Fiber Optic Splice Tray)
 together with heat shrinkable protective sleeve.
( Firstly fix heat shrinkable protective sleeve into the slot, then enlarge the diameter of
fiber ring properly.)
     5.7.2  see Drawing 6
Important issue: pay attention to the twist and bend of fiber.
 
Step Eight - Check up comprehensively
To ensure the technical requirements, the following instructions must be followed:
Fibers with protective coat are fixed with nylon tie at the entrance of FOST.
Grommet should be pressed from inside to outside in order to properly install FOST.
Check whether the internal tighteners and bolt of reinforced core is well tightened
Check whether integrated seal fitting is installed neatly and smoothly without any breakage. If not, level it up with seal tape.
See Drawing 7.
Important issues: If any problems occur, they should be solved right away.

5.9  Step Nine - Install FOSC housing
5.9.1  Tighten fixing bolts of the housing
5.9.2  Tighten octagonal nuts
5.9.3  Either wall mounting or aerial mounting is possible according to the actual installation
requirement.
Wall mounting application: fixing device for wall mounting should be installed at the
bottom of FOSC, which is to be fixed with plastic intumescent screw and bolts.
Aerial mounting application: fix hanging hook on the wall.
5.9.3.  See drawing 8
Important issues: 1. Clean the housing
        2. Tighten bolts in sequence.
 

6. Fiber Optic Splice Closures (FOSC) inspecting and testing items
Inspecting  item Technical Requirements Inspecting type
Routine test (Before leaving factory) Type test
Package Each small package contains one fiber optic splice closure, together with its accessories, tools, installation manual and packing list. full  
 
 
At least 3 sets sampled each time
 
Appearance Intact in shape, no burrs, bubbles, chaps, pores, warps, impurities and other defects, all background colors should be even and continual.
Sign There is a clear sign on the housing, such as name and model of the product, etc.
Fiber storage device The fibers reserved are to be winded in fiber optic splice tray (FOST), the length of fibers housed in FOST is >1.6m, the curved radius is >30mm. During the installation and maintenance, there should be no attenuation on fibers.    
 
 
At least 3 sets sampled each time
 
Electrical jointing device Inside FOSC: metallic components of fiber cables has the functions of electrical putting through, earthing connection and disconnecting. It is possible to install earthing deriving device outside the housing
Sealing performance After sealing according to the stipulated operation procedures, the injected air pressure is 100KPa±5Kpa, when immersed in clean water of normal temperature for 15 minutes, there should be no air bubbles, then observed for 24 hours, there should be no change of air pressure.
Re-sealing performance After reopening and resealing according to the stipulated operation procedures, the injected air pressure is 100KPa±5Kpa, when immersed in clean water of normal temperature for 15 minutes, there should be no air bubbles, then observed for 24 hours, there should be no change of air pressure.
Pull Bearing pull is >= 800N at axle orientation, there should be no breakage on the housing.
Punching Bearing pressure of 2000N/10cm for 1 minutes, there should be no breakage on the housing
Impact Bearing impact energy of 16N•m, 3 times of impacts there should be not breakage on the housing
Bending The spot between the FOSC and seal fitting can bear bending tension of 150N at bending angle of ±450 for 10 circles, there should be no breakage on the housing  
 
 
 
 
Torsion Bearing torsion 50N•m, 10 circle at torsion angle±900,
There should be no breakage on the housing.
Temperature circle Injected air pressure of 60KPa±5 KPa, the temperature circle ranging from -40ºC~+65ºC, 10 times of the circular tests (one circular consists of high temperature for 2 hours + indoor temperature for 2 hours + low temperature for 2 hours + indoor temperature for 2 hours ) when the pressure declines, the amplitude is <=5Kpa, immerse the swatch in clean water of normal temperature for 15 minutes, there should be no air bubbles.
Voltage resistance strength After sealing the FOSC according to the stipulated operation procedures, immerse it in clean water of normal temperature in 1.5m depth for 24 hours, there should be no breakdown or arc over between the metallic components of the FOSC, between metallic components and the ground at DC 15KV for 1 minutes.
Isolating resistance After sealing the FOSC according to stipulated operation procedure, immerse it in clean water in 1.5m depth for 24h, the isolating resistance between the metallic components of the FOSC, between the metallic components and the ground should be >= 2×104MΩ.
 
 
 
 
 
 