Customization: | Available |
---|---|
Type: | Fiber Transceiver |
Certification: | CE, ISO |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1. With PIN Photoelectric converter or WTD (Option)
2. With specialized RF attenuate IC
3. GaAs amplify, power double output, High gain and Low distortion
4. Microprocessor control working status, LED shows all parameters, convenience operation and high stability.
5. Optimization AGC Performance, when the input power Range Is -9~+2dBm, The output level, CTB and CSO keep constantly
6. Backup data communications interface.
Item |
Unit |
Technical Parameter |
|||
Optical Parameter |
|||||
Receive Optical Power |
dBm |
-9 ~ +2 |
|||
Return Loss |
dB |
>45 |
|||
Optical Wavelength |
nm |
1100 ~ 1600 |
|||
Connector Type |
|
FC/APC SC/APC |
|||
Fiber Type |
|
Single Mode |
|||
Circuit Performance |
|||||
C/N |
dB |
≥ 51 -2dBm Input |
|||
C/CTB |
dB |
≥ 65 |
Output Level 108 dBμV Balanced 6dB |
||
C/CSO |
dB |
≥ 60 |
|||
RF Performance |
|||||
Frequency Range |
MHz |
45 ~862 |
|||
Flatness in Band |
dB |
±0.75 |
|||
Rated Output Level |
dBμV |
≥ 108 |
|||
Max Output Level |
dBμV |
≥ 112 |
|||
Output Return Loss |
dB |
≥14 |
|||
Output Impedance |
Ω |
75 |
|||
Electronic Control EQ Range |
dB |
0~10 |
|||
Electronic Control ATT Range |
dBμV |
0~20 |
|||
Return Transmit Performance Parameter |
|||||
Optical Parameter |
|||||
Optical Transmit Wavelength |
nm |
1310±10 |
|||
Output Optical Power |
dBm |
1 ~ 5 |
|||
Connector Type |
|
FC/APC SC/APC |
|||
RF Parameter |
|||||
Frequency Range |
MHz |
5 ~ 65 (or according to the requirement of user) |
|||
Flatness in Band |
dB |
±1 |
|||
Input Level |
dBμV |
85 ~ 90 |
|||
Output Impedance |
Ω |
75 |
|||
General Parameter |
|||||
Supply Voltage |
V |
A: AC 150~265V B: AC 35~90V |
|||
Operating Temperature |
|
-40~60 |
|||
Storage Temperature |
|
-40~65 |
|||
Relative Humidity |
% |
Max 95% No Condensation |
|||
Consumption |
VA |
≤ 30 |
|||
Dimension |
mm |
240L 240W 150H |
Note: The parameter of forward RF is tested under the condition of using GaAs 25 dB double power module in the last stage, if you use other module, the parameter will be slightly different.