Customization: | Available |
---|---|
Certification: | CE |
Condition: | New |
Still deciding? Get samples of US$ 998/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
* 3 GE ports (max 512 IP in): The Data1 & Data2 bi-directional ports, max 512 IP in, 16 IP out The data port (located on the front panel), max 128 IP in
* Max 840Mbps for each GE input * Support accurate PCR adjusting
Input | Input | Max 512 IP input through 3 (front-panel Data port, Data 1 and Data 2) 100/1000M Ethernet Port (SFP interface optional). Each Data1 or Data 2 port can input max 512 IP, while front-panel Data port can input max 128 IP |
||
Transport Protocol | TS over UDP/RTP, unicast and multicast, IGMP V2/V3 | |||
Transmission Rate | Max 840Mbps for each GE input | |||
Mux | Input Channel | 512 | ||
Output Channel | 16/32 | |||
Max PIDs | 180 per channel | |||
Functions | PID remapping(auto/manually optional) | |||
PCR accurate adjusting | ||||
PSI/SI table automatically generating | ||||
Scrambling Parameters |
Max simulscrypt CA | 4 | ||
Scramble Standard | ETR289, ETSI 101 197, ETSI 103 197 | |||
Connection | Local/remote connection | |||
Modulation Parameters |
DVB-C Modulator Sectioon | J.83A | Constellation : 16/32/64/128/256QAM | |
Bandwidth :8M | ||||
J.83B | Constellation : 64QAM/ 256QAM | |||
Bandwidth :6M | ||||
QAM Channel | 16 non-adjacent carrier | |||
Modulation Standard | EN300 429/ITU-T J.83A/B(DVB-C) | |||
Symbol Rate | 5.0~7.0Msps, 1ksps stepping | |||
FEC | RS (204, 188) | |||
RF Output | Interface | 1 F typed output port for 16 carriers, 75Ω impedance | ||
RF Range | 50~960MHz, 1kHz stepping | |||
Output Level | -20dBm~+10dBm(87~117dbµV), 0.1dB stepping | |||
MER | ≥ 40dB | |||
TS output | 16 IP output over UDP/RTP/RTSP, unicast/multicast, 2 (Data1& Data2) 100/1000M Ethernet Ports | |||
System | Network management software (NMS) supporting | |||
General | Demission | 420mm×440mm×44.5mm (WxLxH) | ||
Temperature | 0~45ºC(operation), -20~80ºC(storage) | |||
Power Supply | AC 100V±10%, 50/60Hz or AC 220V±10%, 50/60Hz |
1. What are the payment terms that you support?