Customization: | Available |
---|---|
Application: | Communication |
Type: | Single-mode Fiber |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Cable type | Application |
GYXTW- 8/12/24B1.3 |
Duct installation and aerial installation together with tension strand wire |
ITU-T G.652 | Characteristics of a single-mode optical fibre |
IEC 60794-1-1 | Optical fibre cables-part 1-1: Generic specification-General |
IEC 60794-1-2 | Optical fibre cables-part 1-2: Generic specification-Basic optical cable test procedure |
IEC 60794-3 | Optical fibre cables-part 3: Sectional specification-Outdoor cables |
IEC 60794-3-10 | Optical fibre cables-part 3-10: Outdoor cables-Family specification for duct and direct buried optical communication cables |
IEC 60794-3-11 | Optical fibre cables-Part 3-11: Outdoor cables-Detailed specification for duct and directly buried single-mode optical fibre telecommunication cables |
Optical fibre cables supplied in compliance with these specifications is capable to withstand the typical service condition for a period of THIRTY (30) years without detriment to the operation characteristics of the cable.
Characteristics | Conditions | Specified Values | Units |
Optical characteristics | |||
Attenuation |
1310 nm 1550 nm |
<0.36 <0.22 |
[dB/km] [dB/km] |
Chromatic Dispersion |
1310 nm 1550 nm 1625 nm |
≤3.5 ≤18 ≤22 |
[ps/(nm·km)] [ps/(nm·km)] [ps/(nm·km)] |
Zero dispersion wavelength |
1312±10 |
[nm] |
|
Zero dispersion slope |
≤0.092 |
[ps/(nm2 ·km)] |
|
PMD Maximum Individual Fibre Link Design Value (M=20,Q=0.01%) |
≤0.1 ≤0.06 |
[ps/km] [ps/km] |
|
Cable cutoff wavelengthλ cc |
≤1260 |
[nm] |
|
Mode field diameter (MFD) |
1310 nm 1550 nm |
9.2±0.4 10.3±0.5 |
[μ m] [μ m] |
Core-clad Concentricity |
≤0.5 |
[μ m] |
|
Cladding diameter |
125±1 |
[μ m] |
|
Cladding Non-circularity |
≤0.8 |
[%] |
|
Coating diameter |
245±5 |
[μ m] |
|
Proof test |
≥0.69 |
[Gpa] |
Fibre Color Code |
1 | 2 | 3 | 4 | 5 | 6 |
Blue | Orange | Green | Brown | Grey | White | |
7 | 8 | 9 | 10 | 11 | 12 | |
Red | Black | Yellow | Violet | Pink | Aqua |
Item |
Details |
||
Fiber cores | 812/24 | ||
Loose tube |
Material | PBT | |
Outer diameter (mm) | 2.0/2.0/2.6±0.1 | ||
Tube filling compound |
Jelly |
||
Armoring | Corrugated steel tape | ||
Strength member | Steel wire :2*0.8mm | ||
Sheath |
Thickness(mm) | 2.4/2.4/2.1 | |
Material | PE | ||
Outer diameter(mm) | 8.0 | ||
Net weight (kg/km) | 60/61/62 |
Item | Value |
Tensile performance(N) | 1000 |
Crush(N/100mm) | 1000 |
Operation temperature: | -40ºC~+70ºC |
Installation temperature | -40ºC~+70ºC |
Storage temperature | -40ºC~+70ºC |
Items | Test Method | Requirements |
Tension |
IEC 60794-1-2-E1 Load: According to 3.5 Sample length: Not less than 50m. Duration time: 1min. |
Additional attenuation: ≤0.1dB after test No damage to outer jacket and inner elements |
Crush |
IEC 60794-1-2-E3 Load: According to 3.5 Duration of load: 1min |
Additional attenuation: ≤0.1dB after test No damage to outer jacket and inner elements |
Impact |
IEC 60794-1-2-E4 Radius: 300 mm Impact energy: 10 J Impact number: 1 Impact points: 3 |
Additional attenuation: ≤0.1dB No damage to outer jacket and inner elements |
Bend |
IEC 60794-1-2-E11A Mandrel radius: 10*D Turns:4 Cycles:3 |
Additional attenuation: ≤0.1dB No damage to outer jacket and inner elements |
Repeated bending |
IEC 60794-1-2-E6 Bending radius: 20*D Cycles: 25 Load: 150N |
Additional attenuation: ≤0.1dB No damage to outer jacket and inner elements |
Torsion |
IEC 60794-1-2-E7 Cycles:10 Length under test: 1m Turns: ± 180° Load: 150N |
Additional attenuation: ≤0.1dB No damage to outer jacket and inner elements |
Water Penetration |
IEC 60794-1-2-F5B Time : 24 hours Sample length : 3m Water height : 1m |
No water leakage. |
Temperature cycling |
IEC 60794-1-2-F1 Sample length: at least 1000m Temperature range: -10ºC~+70ºC Cycles: 2 Temperature cycling test dwell time: 12 hours |
The change in attenuation coefficient shall be less than 0.1 dB/km. |
Other parameters | According to IEC 60794-1 |
Both ends of the cable will be sealed with suitable plastic caps to prevent the entry of moisture during shipping, handling and storage. The inner end is available for testing.
1. What are the payment terms that you support?