Customization: | Available |
---|---|
Application: | Local Communication Cable, Fiber Optic Cable, Long Distance Symmetric Cable |
Conductor Material: | Optic Fiber |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Category | Description | Specifications | |
G.652D | |||
Optical Specifications | Attenuation | @1310nm | ≤0.35dB/km |
@1383nm | ≤0.35dB/km | ||
@1550nm | ≤0.22dB/km | ||
@1625nm | ≤0.25dB/km | ||
Attenuation discontinuity | ≤0.05 dB | ||
Attenuation vs. Wavelength | @1285~1330nm | ≤0.05 dB/km | |
@1525~1575nm | ≤0.05 dB/km | ||
Zero Dispersion Wavelength | 1300~1324nm | ||
Zero Dispersion Slope | ≤0.092ps/(nm2.km) | ||
Dispersion | @1310nm | ≤3.5 ps/nm.km | |
@1550nm | ≤18 ps/nm.km | ||
Polarization Mode Dispersion(PMD) | ≤0.2ps/km1/2 | ||
Cable Cutoff Wavelength(λcc) | ≤1260nm | ||
Effective Group Index of Refraction | @1310nm | 1.4675 | |
@1550nm | 1.4681 | ||
Macro bend loss (30mm radius ,100turns) 1625nm | ≤0.1 dB | ||
Geometric Specifications |
Mode Field Diameter | @1310nm | 9.2±0.6μm |
@1550nm | 10.4±0.8μm | ||
Cladding Diameter | 125±1μm | ||
Cladding Non-Circularity | ≤1.0% | ||
Coating Diameter | 245±7μm | ||
Coating/Cladding Concentricity Error | ≤8μm | ||
Core/Cladding Concentricity Error | ≤0.8μm | ||
Mechanical Specifications |
Proof Test level | ≥1.0% | |
Fiber Curl Radius | ≥4.0m | ||
Peak Coating Strip Force | 1.3~8.9N |
Number of fiber | 2~24 | ||
Loose tube | material | PBT (polybutylene terephthalate) | |
diameter | Approx.2.5 mm | ||
Filling compound in loose tube | material | Thixotropic jelly | |
strength member | material | Phosphate steel wire | |
diameter | Approx. 1.0mm×2 | ||
Water blocking material | material | Dry water blocking powders | |
Armour | material | Steel tape coated with polymer on both sides | |
Cable jacket | material | UV-proof middle density black polyethylene | |
Cable diameter Approx. (mm) | 7.6 | ||
Cable weight Approx. (kg/km) | 67 | ||
Maximum allowed tension | 1500 N (fiber strain ≤0.3%) | ||
Crush Resistance | 1000 N/10cm | ||
Minimum radio of flexion | Instalation | 20D* | |
After Instalation | 10D | ||
Operating Temperature | -40~+60ºC |
No. of fiber | 1 | 2 | 3 | 4 | 5 | 6 |
Color of fiber | Blue | Orange | Green | Brown | Grey | White |
No. of fiber | 7 | 8 | 9 | 10 | 11 | 12 |
Color of fiber | Red | Black | Yellow | Violet | Pink | Aqua |
No | Item | Test standard | Method | Acceptance criteria |
1 | Tensile test |
IEC-60794-1-E1 | -Max. Tensile strength:1500N -Sample length:50 meters -Time: 1minutes; |
-Fiber strain at maximum Load: max. 0.33% -Attenuation increase≤0.05dB |
2 | Crush test |
IEC-60794-1-E3 | -Load:1000N -Time: 1 minutes -Length: 100mm |
-No splits or cracks in the outer jacket; -Attenuation increase<0.10dB, |
3 | Impact test |
IEC-60794-1-E4 | -Impact energy: 450g - Height:1 meter -Impact points: min.1 --Number of impacts: 5 |
-No splits or cracks in the outer jacket -Attenuation increase≤0.10dB |
4 | Repeated bending | IEC-60794-1-E6 | -R=20×cable outer diameter -1m cable length with 150N weight,30 cycles |
- No splits or cracks in the outer jacket -Attenuation increase ≤0.10dB |
5 | Torsion test |
IEC-60794-1-E7 | -1m cable length with 150N weight -±90 degrees, 10 cycles |
- No splits or cracks in the outer jacket -Attenuation increase ≤0.10B |
6 | Bending test |
IEC-60794-1-E11 | -Diameter of mandrel: 20×D -Number of turns/helix:10 -Number of cycles: 5 |
- No splits or cracks in the outer jacket - No fiber break |
7 | Temperature cycling test | IEC-60794-1-F1 | -Temperature step: +20ºC→-40ºC→+60ºC→-40ºC→ +60ºC→+20ºC -Time per each step: 12 hrs -Number of cycles: 2 cycles |
-Attenuation variation for reference value(the attenuation to be measured before test at +20±3ºC) ≤0.05dB, |
8 | Water penetration test | IEC-60794-1-F5 | -Water height: 1m -Sample length:3m -Duration of test: 24hrs |
-No water leakage at the end of the sample |
9 | Drip test | IEC-60794-1-E14 | -Five 0.3m samples suspended vertically in a climate chamber, raised temperature to +70ºC | -No filling compound shall drip from tubes after 24 hr |