1. Scope of application
This Installation Manual suits for the Fiber Optic Splice Closure (Hereafter abbreviated as FOSC), as the guidance of proper installation.
The scope of application is: aerial and wall-mounting. The ambient temperature ranges from -40 to 65ºC.
2. Basic structure and configuration
2.1 Dimension and capacity
Outside dimension (LxWxH) |
280x200x90 (mm) |
Weight (excluding outside box) |
1200g-1500g |
Number of inlet/outlet ports |
max. 4 pieces |
Diameter of fiber cable |
Φ8-Φ14 (mm) |
Capacity of FOSC |
Bunchy: 6-96 (Cores) |
2.2 Main components
No. |
Name of components |
Quantity |
Usage |
Remarks |
1 |
FOSC cover |
1 piece |
Protecting fiber cable splices in whole |
Internal diameter:
205x146 (mm) |
2 |
FOSC bottom |
1 piece |
Fixing reinforced core, fiber cable and FOST |
Internal diameter:
205x146 (mm) |
3 |
Fiber optic splice tray
(FOST) |
max. 4 pieces (bunchy) |
Fixing heat shrinkable protective sleeve and holding fibers |
Suitable for:
Bunchy:6,12,24(cores) |
4 |
Integrated seal fitting |
1 set |
Sealing between FOSC cover and FOSC bottom |
|
5 |
Port plug |
2 pieces |
Sealing empty ports |
|
6 |
Earthing deriving device |
1 set |
Deriving metallic components of fiber cable in FOSC for earthing connection. |
Configuation as per requirement. |
2.3 Main accessories and special tools
No. |
Name of accessories |
Quantity |
Usage |
Remarks |
1 |
Heat shrinkable protective sleeve |
|
Protecting fiber splices |
Configuration as per capacity |
2 |
Nylon tie |
|
Fixing fiber with protective coat |
Configuration as per capacity |
3 |
Seal tape |
1 roll |
Enlarging diameter of fiber cable which fits in with seal fitting |
Configuration as per specification |
4 |
Hanging hook |
1 set |
For aerial use |
Configuration as per requirement |
5 |
Fixing device |
1 set |
|
Configuration as per requirement |
6 |
Earthing wire |
1 piece |
Putting through between earthing devices |
To put through while required |
7 |
Abrasive cloth |
1 piece |
Scratching fiber cable |
|
8 |
Labeling paper |
1 piece |
Labeling fiber |
|
9 |
Special wrench |
1 piece |
Fixing octagonal nut (plastic) |
|
10 |
Buffer tube
|
To be decided by customers |
Hitched to fibers and fixed with FOST, managing buffer |
Configuration as per requirement |
11 |
Desiccant |
1 bag |
Put into FOSC before sealing for desiccanting air. |
|
3. Necessary tools for installation
3.1 Supplementary materials (to be provided by operator)
Name of materials |
Usage |
Scotch tape |
Labeling, temporarily fixing |
Ethyl alcohol |
Cleaning |
Gauze |
Cleaning |
3.2 Special tools (to be provided by operator)
Name of tools |
Usage |
Fiber cutter |
Cutting off fibers |
Fiber stripper |
Strip off protective coat of fiber cable |
Combo tools |
Assembling FOSC |
3.3 Universal tools (to be provided by operator)
Name of tools |
Usage and specification |
Band tape |
Measuring fiber cable |
Pipe cutter |
Cutting fiber cable |
Electrical cutter |
Take off protective coat of fiber cable |
Combination pliers |
Cutting off reinforced core |
Screwdriver |
Crossing/Paralleling screwdriver |
Scissor |
|
Waterproof cover |
Waterproof, dustproof |
Metal wrench |
Tightening nut of reinforced core |
3.4 Splicing and testing instruments (to be provided by operator)
Name of instruments |
Usage and specification |
Fusion Splicing Machine |
Fiber splicing |
OT DR |
Splicing testing |
Provisional splicing tools |
Provisional testing |
Notice: The above-mentioned tools and testing instruments should be provided by the operators themselves.