1U 19'' Rack Mount Fiber Optic MPO Cassette with Fusion Splicing Tray
MPO Brief Introduction
MPO Pre-terminated Cabling System Solution
Custom made for you by SOFTEL. It is custom made for your datacenter and other high-end cabling solution with pre-termination MPO.
SOFTEL MPO adopts Corning CLear Curve series OM3/OM4 fiber cable, plus the connectors from US Connector MTP products. All the production is done in SOFTEL factory facility to ensure the system performance and quality.
Modular and snapping fit design, which offer great convenience to installers at the site for installations as well as future maintenances and services. With the universal system and MPO interface, it will provide trouble-free connection between fiber cable and equipments as well as ensure the channel has the best flexibility, compatibility and reliability.
Product Line Construction
SOFTEL pre-terminated MPO Patch Cord series offers the solution from trunk cables to extended trunk cables, to hybrid trunk cables, to cassette modules, to MPO adapter panels, to direct patch panels, to patch panels in both MPO classification of G class(normal class) and L-class(super low loss).
MPO Solution Features
Ideal for high density datacenter application, choice from 12 to 144-fiber cable.
Adopt MTP/MPO connectors single 12-fiber push/pull connector.
Custom made cable length.
Pre-wrapped cable pulling eye provide additional protection to the cable during shipping.
Cable distribution protection devise, ensure easy cable laying and neat installation.
Pre-terminated cables can take 450N pulling force when installed in the slots.
Available in LSZH, OFNR, OFNP, all can be custom made. Single Mode MPO
MPO Solution Diagram
Part of the MPO Workshop
MPO Parameters
Pre-terminated System Installation
In order to ensure entire connection is in a unify condition, we need to first install patch panel, cassette module and related mounting hardware. Then, say the cables in designed cable passage position, remove all the protection caps and wraps, connect MPO and to all the related MPO sockets, mount and secure the cables with cable ties, simple as that.
Installation Steps
1. Install accessories and hardware
2. Cable laying
3. Plug device
4. Cable mounting
|
|
Multi Mode |
Single Mode |
IL |
MPO |
Single max :0.35db (L)
Single Max : 0.60db (G) |
Single max :0.35db (L)
Single max :0.75db (G) |
|
LC |
MAX :0.10dB(L)
MAX :0.15 db (G) |
max :0.30db |
RL |
MPO |
>20DB |
>60DB (8 degree Angle Polish ) |
|
LC |
>30db |
>50 db (UPC) >60DB(APC) |
Mechanical |
MPO |
<0.2DB, 200 times insertion |
|
|
LC |
<0.2db, 500times in s ertion |
|
|
Working Temp |
-20~ +60 'C |
Environment |
Storage Temp |
-40~ + 70'C |
|
Install Temp |
-5~ + 50'C |